Products

Mannul call point (MCP)

A Manual Call Point (MCP) allows users to manually trigger the fire alarm in case of an emergency. Designed with a break-glass or resettable mechanism, it ensures fast, visible activation

Manual Call Point (MCPs)

Operating Voltage: 24V DC (Conventional)

• Reset Type: Glass

• Indicator: LED for alarm status

Material: MS Metal

• Mounting: Surface/Flush

• Compliance: EN 54

• Colour: Red

MCP in plastic

The Manual Call Point (MCP) is a fire alarm device that allows individuals to manually trigger the fire alarm system during an emergency. The plastic variant is lightweight, durable, and corrosion-resistant, making it suitable for indoor installations in offices, commercial spaces, and industrial buildings.

Material: High polycarbonate plastic

Colour: Red (standard), with clear markings

Activation Method: Break glass or resettable element

Operating Voltage: 24V DC

Current Rating: <100mA

Mounting: Surface or flush

Operating Temperature: -10°C to +55°C

Protection Class: IP44 or higher (indoor use)

2-zone panel

The 2-zone fire alarm panel is designed for small to medium-sized buildings where limited fire detection zones are sufficient. It controls and monitors fire alarm devices like detectors and MCPs across two separate areas. Easy to install and maintain, this panel is ideal for shops, offices, and small warehouses.

Zones: 2 (Conventional)

Material: Metal Cabinet

Power Supply: 230V AC ±10%, 50Hz

Backup Battery: 12V 7Ah (Sealed Lead Acid)

Output: Sounder Output – 24V DC @ 500mA per zone

Indications: Fire, Fault, Power, Zone-wise LEDs

Controls: Mute Buzzer, Reset, Lamp Test, Silence Alarm

4-zone panel

A 4-zone panel is suited for medium to large installations needing more area coverage. It manages up to four detection zones independently, enhancing fire location precision. Suitable for schools, industrial units, and residential complexes.

Zones: 4 (Conventional)

Material: Powder-coated metal cabinet

Power Supply: 230V AC ±10%, 50Hz

Battery Backup: 2 x 12V 7Ah SLA batteries

Sounder Output: 24V DC @ 500mA per zone

Display/Indications: Zone-wise Fire & Fault LEDs, System Status

Control Buttons: Reset, Silence, Buzzer Mute, Drill

Relay Outputs: Fire, Fault, External Hooter

Public Address (PA) System

A Public Address system is used for emergency announcements, evacuation alerts, and general communication within a building. Integrated with fire alarm systems, it ensures voice instructions reach all occupants. Suitable for schools, factories, malls, offices, and large buildings.

System Type: Central Amplifier + Distributed Speakers

Input Power: 230V AC / Backup 24V DC

Amplifier Output: 30W to 500W (as per requirement)

Microphone Type: Handheld or gooseneck with push-to-talk

Speakers: Wall/Ceiling mount or horn speakers (6W/10W/15W)

Zones: Single or multi-zone (expandable)

Frequency Response: 100 Hz – 15 kHz

Material: Metal cabinet for console, ABS body for speakers

Features:

  • Mic priority override
  • Aux input for BGM
  • Fire alarm interface
  • Volume control per zone (optional)

Compliance: IS 2266, BIS/CE Certified

Application: Offices, factories, educational institutions, hospitals

4-Wire Looping (Fire Alarm/PA System Cabling)

4-wire looping is used in addressable and integrated fire alarm systems, where two wires handle power and two carry signal/data. It ensures stable communication and proper system function over long distances. Also used in PA systems for voice + power transmission.

Cable Type: 4-core FRLS/FRLSH (Fire Retardant Low Smoke/Zero Halogen)

Core Specification: 1.0mm² / 1.5mm² / 2.5mm² (as required)

Insulation: PVC / XLPE / LSZH

Voltage Rating: 300/500V

Color Code: Red/Black (Power), Blue/White (Signal)

Outer Sheath: PVC or LSZH (Red preferred)

Shielding: Optional (for data noise protection)

Standard: IS 694 / IEC 60332 / EN 50265

Packaging: 90M/100M coil or drum

Application:

  • Fire alarm system (addressable loop)
  • PA/BGM system
  • Security & emergency systems

Hooter in Metal

Fire Alarm Hooters provides a high-decibel audio warning to alert occupants in case of a fire emergency. Designed for fast activation and long-range sound coverage.

• Sound Output: 100-110 dB at 1 meter

• Operating Voltage: 24V DC

• Current Consumption: <150mA

• Housing: ABS, IP44 rated

• Mounting: Wall/Ceiling

• Operating Temp: -10°C to +55°C

Material: MS Metal

• Colour: Red

hooter in plastic

The plastic fire alarm hooter is an audio signalling device used to alert occupants in case of fire or emergency. Built from polycarbonate plastic, it is lightweight, weather-resistant (for indoor use), and provides loud sound output suitable for commercial and industrial installations.

Material: Polycarbonate plastic

Operating Voltage: 12V / 24V DC (model dependent)

Current Consumption: <100 mA

Sound Output: ≥ 90 – 100 dB @ 1 meter

Mounting Type: Wall-mounted (surface)

Tone Type: Continuous or selectable tone (optional)

Colour: Red (standard)

Operating Temperature: -10°C to +55°C

Hooter for the office in plastic

The white fire alarm hooter is designed for indoor and office environments where a clean and professional appearance is required. Made from high-grade ABS plastic, it delivers reliable audible alerts during emergencies without disrupting the aesthetic of modern interiors.

Material: ABS plastic (flame-retardant)

Colour: White (suitable for office interiors)

Operating Voltage: 12V / 24V DC

Current Consumption: <120mA

Sound Output: ≥ 90 dB @ 1 meter

Mounting Type: Wall or ceiling (surface-mounted)

Tone Type: Soft, continuous or pulsed tone (optional)

Operating Temperature: 0°C to +50°C

Strobe Light

The plastic-body strobe is a visual alerting device used in fire alarm systems. It emits a bright flashing light to alert occupants, especially useful in noisy environments or for people with hearing impairments. Ideal for indoor applications like offices, hospitals, and commercial areas.

Material: Flame-retardant ABS or polycarbonate plastic

Colour: Red or white housing with transparent lens

Flash Type: Xenon or LED-based

Operating Voltage: 12V / 24V DC

Current Consumption: <100mA

Flash Rate: 60–90 flashes per minute

Mounting Type: Wall-mounted (surface)

Operating Temperature: -10°C to +55°C

Ingress Protection: IP44 (indoor use)

Response indicator (RI) metal

Response Indicator (RI) is designed to visually indicate the activation of fire detectors that are installed in concealed, inaccessible, or remote locations such as false ceilings, shafts, or behind decorative panels.

Function: Visual alert for active detector zones

LED Type: High-brightness red LED

Visibility: >10 meters

Wiring: 2-wire, parallel connection to detector base

Power Supply: 24V DC

Mounting Type: Surface or flush mount

Material: MS metal

Colour: White

combine mcp and hooter

The combined MCP with hooter unit integrates a manual call point and audible alarm into a single compact device. It allows users to manually trigger the alarm while simultaneously sounding a loud hooter to alert nearby occupants. Made from high-quality MS, it is ideal for schools, offices, shops, and small industrial setups.

Material: High-impact ABS or polycarbonate plastic

Colour: Red (standard)

Operating Voltage: 12V / 24V DC

Current Consumption: <150mA

Activation: Break glass or resettable MCP

Sound Output: ≥ 90 dB @ 1 meter

Mounting Type: Wall-mounted (surface)

Indications: Manual activation + audible alert

Operating Temperature: -10°C to +55°C

Ingress Protection: IP44 (indoor use)

smoke detector

A smoke detector senses smoke particles in the air to identify early signs of fire. Made of fire-retardant plastic, it is widely used in homes, offices, commercial spaces, and indoor industrial environments for early fire warning.

Type: Photoelectric (Optical)

Material: Flame-retardant ABS plastic

Operating Voltage: 9V – 24V DC

Current Consumption: Standby <20µA, Alarm <100mA

Indication: LED blinks in standby, glows in alarm

Alarm Output: Normally open dry contact or signal to panel

Mounting Type: Ceiling-mounted

Operating Temperature: -10°C to +50°C

heat detector

A heat detector senses a rapid rise in temperature or a fixed high temperature to detect fire. Ideal for kitchens, boiler rooms, and dusty areas where smoke detection may not be suitable.

Type: Fixed temperature or rate-of-rise

Material: ABS plastic housing

Operating Voltage: 9V – 24V DC

Alarm Temperature: Fixed at 57°C or 75°C (customizable)

Current Consumption: Standby <15µA, Alarm <60mA

Output Signal: Normally open dry contact

Mounting Type: Ceiling surface mount

Operating Temp.: -10°C to +60°C

multi detector

The multi-detector combines both smoke and heat sensing technologies in one unit, improving accuracy and reducing false alarms. Suitable for areas where both types of fire risks are present.

Type: Photoelectric smoke + rate-of-rise heat

Material: Flame-retardant plastic

Operating Voltage: 9V – 24V DC

Current Consumption: Standby <25µA, Alarm <100mA

Alarm Output: Relay output or signal to fire panel

Indication: LED (blinking/steady)

Mounting Type: Ceiling-mounted

Operating Temp.: -10°C to +55°C

duct detector

A duct detector monitors smoke within HVAC air ducts and triggers alarms if smoke is detected in the airflow. Essential for air-handling systems in commercial buildings, malls, hospitals, and industrial facilities. Typically installed with sampling tubes inside the duct.

Type: Photoelectric smoke sensor in duct housing

Material: ABS plastic or metal enclosure (model dependent)

Operating Voltage: 24V DC

Current Consumption: <100mA

Detection Method: Air sampling from duct airflow

Indications: LED status – Power/Alarm/Fault

Output: Alarm relay (NO/NC), supervisory relay

Sampling Tubes: Adjustable (up to 2.5 ft to 6 ft)

Mounting: Directly on air duct (external with probe inside)

Operating Temp.: 0°C to +50°C

beam detector

Beam detectors cover large open areas like warehouses, auditoriums, and shopping malls. They project an infrared beam across a wide space and trigger an alarm when smoke obstructs the beam.

Type: Optical beam smoke detector (reflective or dual unit)

Range: 5 – 100 meters (model specific)

Operating Voltage: 24V DC

Current Consumption: <50mA (standby), <120mA (alarm)

Alignment: Manual or auto-align (advanced models)

Indications: LED for alignment, fault, and alarm status

Response Time: Typically <10 seconds

Operating Temp.: -10°C to +55°C

Application: Warehouses, malls, airports, atriums, large halls

key box

Fire Alarm Key metal enclosure designed to store emergency keys for fire alarm systems. Built with high-grade materials, it ensures quick access during fire emergencies while maintaining safety and durability

Access Method: Break glass to retrieve key

Application: Emergency fire key access

Glass Type: Breakable Acrylic/Tempered Glass

Mounting: Wall Mounted

Material: MS metal

Colour: Red

junction/back box

Junction Box is designed to securely house fire alarm system wiring and terminations. Its rugged construction ensures reliable protection in all environments.

Ingress Protection: IP 44 (optional higher IP rating)

Application: Cable Termination & Routing

Entry Size: 20mm (standard)

Mounting: Surface or Flush Mounted

Material: MS Metal

Colour: White

hammer

Metal Break Glass Hammer is a compact and reliable tool designed for emergency access to key boxes. Built for durability, it ensures fast and safe break-glass activation when seconds count.

Application: Emergency glass break for key box access

Attachment: Metal chain

Mounting: Chain-attached or Wall-mounted

Material: MS Metal

Colour: Black

fire extinguisher

Fire extinguishers are essential first-response tools used to control or extinguish fires in the early stages. They are available in various types based on the fire risk and environment, including ABC Powder, CO₂, Foam, and Water. Each type is designed for specific fire classes (A, B, C, E) and environments.